Cisco及华为网络技术论坛
您的位置:
首页 > Vlan9.com > Cisco解决方案 > 正文 阅读排行榜

CISCO交换机命令全集加说明


来源:ChinaITLab 作者: 出处:Vlan9.com 2007-12-22 进入论坛

  Table of Contents
  
  Command Descriptions
  
  address-violation
  autobaud
  back-pressure
  banner motd
  bridge (forwarding-time)
  bridge-group
  bridge-group (allow-overlap)
  bridge-group (enable)
  bridge (hello-time)
  bridge (max-age)
  bridge (priority)
  cdp (advertise-v2)
  cdp (enable)
  cdp (holdtime)
  cdp (timer)
  cgmp
  cgmp (hold-time)
  cgmp (leave-processing)
  cgmp (remove)
  cgmp (reserved)
  clear (cgmp)
  clear (dns-cache)
  clear (counters)
  clear (mac-address-table)
  clear (uplink-fast statistics)
  clear (vtp statistics)
  cluster
  configure
  copy (nvram tftp)
  copy (tftp)
  copy (xmodem)
  databits
  delete (nvram)
  delete (vtp)
  description
  disable
  duplex
  ecc
  enable
  enable (password)
  enable (secret)
  enable (use-tacacs)
  end
  exit
  fddi (authorization)
  fddi (auth-string)
  fddi (notify-timer)
  fddi (novell-snap-translation)
  fddi (unmatched-snap-translation)
  hostname
  interface
  ip (address)
  ip (default-gateway)
  ip (domain-name)
  ip (http port)
  ip (http server)
  ip (mgmt-vlan)
  ip (name-server)
  line console
  login (tacacs)
  mac-address-table (aging-time)
  mac-address-table (permanent)
  mac-address-table (restricted static)
  menu
  modem (dialin)
  modem (init-string)
  monitor-port
  monitor-port (monitored)
  monitor-port (port)
  multicast-store-and-forward
  network-port
  pagp-port-priority
  parity
  password-thresh
  ping
  port (block)
  port-channel (mode)
  port-channel (preserve-order)
  port-channel (template-port)
  port secure
  port secure (clear)
  reload
  reload (in)
  rip
  service (config)
  session
  show (bridge-group)
  show cdp (interface)
  show cdp (neighbors)
  show (cgmp)
  show cluster
  show (history)
  show (interfaces)
  
  Command Descriptions
  This chapter is a command-by-command description of the firmware version 9.00 CLI commands for the Catalyst 1900 series and Catalyst 2820 series switches.
  address-violation
  Use the address-violation global configuration command to specify the action for a port address violation. Use the no address-violation command to set the switch to its default value (suspend).
  address-violation {suspend | disable | ignore}
  no address-violation
  Syntax Description
  suspend Suspend port on address violation. A suspended port is temporarily disabled until a certain number of frames with the proper address is received.
  disable Disable port on address violation.
  ignore Ignore address violation.
  
  Default
  The port is suspended on address violation.
  Command Mode
  Global configuration
  Usage Guidelines
  An address violation occurs when a secured port receives a source address that has been assigned to another secured port or when a port tries to learn an address that exceeds the address-table size limit.
  Example
  This command causes the switch to disable the port on address violation.
  hostname(config)# address-violation disable
  Related Commands
  port secure
  show (port system)
  autobaud
  Use the autobaud line-configuration command to enable remote baud-rate matching. Use the no autobaud command to disable remote baud-rate matching.
  autobaud
  no autobaud
  Syntax Description
  This command has no arguments or keywords.
  Default
  Remote baud-rate matching is enabled.
  Command Mode
  Line configuration
  Example
  This example shows how to enable remote baud-rate matching.
  hostname(config-line)# autobaud
  Related Commands
  databits
  line console
  modem (dialin)
  parity
  show (line)
  show (terminal)
  speed
  stopbits
  terminal
  back-pressure
  Use the back-pressure global configuration command to enable back pressure. Use the no back-pressure command to disable back pressure.
  back-pressure
  no back-pressure
  Syntax Description
  This command has no arguments or keywords.
  Default
  Back pressure is disabled.
  Command Mode
  Global configuration
  Usage Guidelines
  When the back-pressure command is enabled, the switch forces a collision when there is no buffer to receive frames. This collision causes the transmitter to retransmit dropped frames immediately, increasing performance. The command is valid only for a 10BaseT port operating in half-duplex mode.
  Example
  This example shows how to enable back pressure.
  hostname(config)# back-pressure
  Related Commands
  configure
  duplex
  show (interfaces)
  show (port system)
  banner motd
  Use the banner motd global configuration command to set the message-of-the-day (MOTD) banner. Use the no banner motd command to remove the banner.
  banner [motd] d message d
  no banner [motd]
  Syntax
  motd Optional command acronym for "message of the day."
  d Delimiting character---a pound sign (#), for example. Do not use the delimiting character in the banner message.
  message Message text up to 400 characters or 20 lines.
  
  Default
  No MOTD is set.
  Command Mode
  Global configuration
  Usage Guidelines
  When configuring a multiline banner, the multiline help prompt displays after you enter the first line of the banner:
  Enter TEXT message. End with the character c
  
  where c is the delimiting character you choose.
  When a MOTD banner is set, it displays at the login screen to the serial port console and all telnet connections (except the rcommand connections from a command switch). The maximum size of the banner is 400 characters or 20 lines, whichever is reached first.
  Examples
  This example sets the MOTD banner to Empowering the Internet Generation.
  hostname(config)# banner motd # Empowering the Internet Generation #
  
  This example shows how to set the MOTD banner message with line feeds.
  hostname(config)# banner #
  
  Enter TEXT message. End with the character #.
  Line 1 is now up.
  Line 2 is still down.
  #
  
  This example shows how to remove the MOTD banner.
  hostname(config)# no banner motd
  Related Commands
  None
  bridge (forwarding-time)
  Use the bridge forwarding-time global configuration command to set the Spanning-Tree Protocol (STP) forward-delay time for a particular bridge group. Use the no bridge forwarding-time command to reset the forward-delay time to its default value.
  bridge bridge-group forwarding-time time
  no bridge bridge-group forwarding-time
  Syntax Description
  bridge-group Number from 1 to 4.
  time Number from 4 to 30 seconds.
  
  Default
  The default is 15 seconds.
  Command Mode
  Global configuration
  Usage Guidelines
  This command is available only when bridge groups are enabled.
  Example
  The following example shows how to set the forward-delay time to 10 seconds for bridge-group 1.
  hostname(config)# bridge 1 forwarding-time 10
  Related Commands
  bridge (hello-time)
  bridge (max-age)
  bridge (priority)
  bridge-group (allow-overlap)
  bridge-group (enable)
  show (bridge-group)
  show (spantree)
  spantree
  bridge-group
  Use the bridge-group interface configuration command to modify the assignments of ports to bridge groups. Use the no bridge-group command to remove ports from a bridge group.
  bridge-group bridge-group
  no bridge-group bridge-group
  Syntax Description
  bridge-group Number from 1 to 4.
  
  Default
  All ports are assigned to bridge group 1.
  Command Mode
  Interface configuration
  Usage Guidelines
  This command is available only when bridge groups are enabled.
  If bridge groups can overlap, the bridge-group command adds a port to the bridge group specified by the bridge-group argument. If bridge groups cannot overlap, the port is moved from its current bridge group to the specified bridge group.
  Example
  The following example shows how to assign the Ethernet port 0/1 to bridge group 2:
  hostname(config)# interface eth 0/1
  hostname(config-if)# bridge-group 2
  Related Commands
  bridge (forwarding-time)
  bridge (hello-time)
  bridge (max-age)
  bridge (priority)
  bridge-group (allow-overlap)
  bridge-group (enable)
  show (bridge-group)
  show (spantree)
  spantree
  bridge-group (allow-overlap)
  Use the bridge-group allow-overlap global configuration command to allow ports to belong to multiple bridge groups. Use the no bridge-group allow-overlap command to prevent ports from belonging to multiple bridge groups.
  bridge-group allow-overlap
  no bridge-group allow-overlap
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  Ports are prevented from belonging to multiple bridge groups.
  Command Mode
  Global configuration
  Usage Guidelines
  This command is available only when bridge groups are enabled.
  You cannot disable overlapping bridge groups when ports belong to multiple bridge groups.
  Example
  The following example shows how to permit ports to become members of multiple bridge groups.
  hostname(config)# bridge-group allow-overlap
  Related Commands
  bridge (forwarding-time)
  bridge (hello-time)
  bridge (max-age)
  bridge (priority)
  bridge-group
  bridge-group (enable)
  show (bridge-group)
  show (spantree)
  spantree
  bridge-group (enable)
  Use the bridge-group enable global configuration command to enable port grouping using bridge groups. Use the no bridge-group enable command to use virtual LANs (VLANs) as the port grouping method.
  bridge-group enable
  no bridge-group enable
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  Bridge groups are disabled.
  Command Mode
  Global configuration
  Usage Guidelines
  When you use the bridge-group enable command or the no bridge-group enable command, the switch resets.
  When bridge groups are disabled, the command bridge-group enable is the only available bridge-group command. The following switch-feature commands are not available when bridge groups are enabled:
  clear (vtp statistics) show (vlan-membership) trunk-vlan
  ip (mgmt-vlan) show (vlan-membership server) uplink-fast
  pagp-port-priority show (vtp) uplink-fast (multicast-rate)
  port-channel (mode) show (vtp statistics) vlan
  port-channel (preserve-order) spantree-option (vlan) vlan-membership
  port-channel (template-port) spantree-template (forwarding-time) vlan-membership (reconfirm)
  show (spantree-option) spantree-template (hello-time) vlan-membership (server)
  show (spantree-template) spantree-template (max-age) vlan-membership (server retry)
  show (trunk) spantree-template (priority) vtp
  show (uplink-fast) spantree-template (vlan) vtp trunk pruning-disable
  show (vlan) trunk
  
  Example
  The following example shows how to enable bridge groups:
  hostname(config)# bridge-group enable
  Related Commands
  bridge (forwarding-time)
  bridge (hello-time)
  bridge (max-age)
  bridge (priority)
  bridge-group
  bridge-group (allow-overlap)
  show (bridge-group)
  show (spantree)
  spantree
  bridge (hello-time)
  Use the bridge hello-time global configuration command to configure the Spanning-Tree Protocol (STP) hello time for a bridge group. Use the no bridge hello-time command to use the default value.
  bridge bridge-group hello-time time
  no bridge bridge-group hello-time
  Syntax Description
  bridge-group Number from 1 to 4.
  time Number from 1 to 10 seconds.
  
  Default
  The time argument default is 2 seconds.
  Command Mode
  Global configuration
  Usage Guidelines
  This command is available only when bridge groups are enabled.
  Example
  The following example shows how to configure a 3-second STP hello time for bridge group 2.
  hostname(config)# bridge 2 hello-time 3
  Related Commands
  bridge (forwarding-time)
  bridge (max-age)
  bridge (priority)
  bridge-group
  bridge-group (allow-overlap)
  bridge-group (enable)
  show (bridge-group)
  show (spantree)
  spantree
  bridge (max-age)
  Use the bridge max-age global configuration command to configure the maximum age time in Spanning-Tree Protocol (STP) for a bridge group. Use the no bridge max-age command to set the argument to its default value.
  bridge bridge-group max-age time
  no bridge bridge-group max-age
  Syntax Description
  bridge-group Number from 1 to 4.
  time Number from 6 to 40 seconds.
  
  Default
  The time argument default is 20 seconds.
  Command Mode
  Global configuration
  Usage Guidelines
  This command is available only when bridge groups are enabled.
  Example
  The following example shows how to set the maximum age time for STP to 22 seconds for bridge group 1.
  hostname(config)# bridge 1 max-age 22
  Related Commands
  bridge (forwarding-time)
  bridge (hello-time)
  bridge (priority)
  bridge-group
  bridge-group (allow-overlap)
  bridge-group (enable)
  show (bridge-group)
  show (spantree)
  spantree
  bridge (priority)
  Use the bridge priority global configuration command to configure the Spanning-Tree Protocol (STP) bridge priority for a bridge group. Use the no bridge priority command to reset the bridge priority to its default value.
  bridge bridge-group priority priority
  no bridge bridge-group priority priority
  Syntax Description
  bridge-group Number from 1 to 4.
  priority Number from 1 to 65535.
  
  Default
  The priority default is 32768.
  Command Mode
  Global configuration
  Usage Guidelines
  This command is available only when bridge groups are enabled.
  Example
  The following example shows how to configure STP bridge priority to 33000 for bridge group 1.
  hostname(config)# bridge 1 priority 33000
  Related Commands
  bridge (forwarding-time)
  bridge (hello-time)
  bridge (max-age)
  bridge-group
  bridge-group (allow-overlap)
  bridge-group (enable)
  show (spantree)
  spantree
  cdp (advertise-v2)
  Use the cdp advertise-v2 global configuration command to enable Cisco Discovery Protocol version 2 (CDPv2) on all switch interfaces. Use the no cdp advertise-v2 command to disable CDPv2 on the switch.
  cdp advertise-v2
  no cdp advertise-v2
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  CDPv2 is enabled.
  Command Mode
  Global configuration
  Example
  The following example shows how to enable CDPv2 on all switch interfaces.
  hostname(config)# cdp advertise-v2
  Related Commands
  cdp (enable)
  cdp (holdtime)
  cdp (timer)
  show cdp (interface)
  show cdp (neighbors)
  cdp (enable)
  Use the cdp enable interface configuration command to enable Cisco Discovery Protocol (CDP) on a port interface. Use the no cdp enable command to disable CDP on an interface.
  cdp enable
  no cdp enable
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  CDP is enabled on all interfaces.
  Command Mode
  Interface configuration
  Usage Guidelines
  The cdp enable command is not available on repeater ports.
  Example
  The following example shows how to disable CDP on Fast Ethernet port interface 0/27.
  hostname(config)# interface fastethernet 0/27
  hostname(config-if)# no cdp enable
  Related Commands
  cdp (advertise-v2)
  cdp (holdtime)
  cdp (timer)
  show cdp (interface)
  show cdp (neighbors)
  cdp (holdtime)
  Use the cdp holdtime global configuration command to set the Cisco Discovery Protocol (CDP) hold time. Use the no cdp holdtime command to use the default value.
  cdp holdtime holdtime
  no cdp holdtime
  Syntax Description
  holdtime Number of seconds receiver keeps packet (5 to 255).
  
  Default
  180 seconds
  Command Mode
  Global configuration
  Example
  This example shows how to set the CDP holdtime to 15 seconds.
  hostname(config)# cdp holdtime 15
  Related Commands
  cdp (advertise-v2)
  cdp (enable)
  cdp (timer)
  show cdp (interface)
  show cdp (neighbors)
  cdp (timer)
  Use the cdp timer global configuration command to specify the rate at which Cisco Discovery Protocol (CDP) packets are sent. Use the no cdp timer command to reset the CDP rate to the default value.
  cdp timer timer
  no cdp timer
  Syntax Description
  timer Number between 5 and 900 seconds.
  
  Default
  60 seconds
  Command Mode
  Global configuration
  Example
  This example shows how to set the CDP packet rate to once in 5 seconds.
  hostname(config)# cdp timer 5
  Related Commands
  cdp (advertise-v2)
  cdp (enable)
  cdp (holdtime)
  show cdp (interface)
  show cdp (neighbors)
  cgmp
  Use the cgmp global configuration command to enable Cisco Group Management Protocol (CGMP) functionality on a switch. Use the no cgmp command to disable CGMP.
  cgmp
  no cgmp
  Syntax Description
  This command has no arguments or keywords.
  Default
  CGMP is enabled.
  Command Mode
  Global configuration
  Example
  This example shows how to enable CGMP on a switch.
  hostname(config)# cgmp
  Related Commands
  cgmp (hold-time)
  cgmp (leave-processing)
  cgmp (remove)
  clear (cgmp)
  show (cgmp)
  cgmp (hold-time)
  Use the cgmp hold-time global configuration command to set the Cisco Group Management Protocol (CGMP) hold time. Use the no cgmp hold-time command to reset the default hold time.
  cgmp hold-time hold_time
  no cgmp hold-time
  Syntax Description
  holdtime Number between 5 and 900 seconds.
  
  Defaults
  Default hold time is 600 seconds.
  Command Mode
  Global configuration
  Example
  This example shows how to set the CGMP hold time to 40 seconds.
  hostname(config)# cgmp hold-time 40
  
  This example shows how to reset the CGMP hold time to its default value.
  hostname(config)# no cgmp hold-time
  Related Commands
  cgmp
  cgmp (leave-processing)
  cgmp (remove)
  clear (cgmp)
  show (cgmp)
  cgmp (leave-processing)
  Use the cgmp (leave-processing) global configuration command to enable Cisco Group Management Protocol (CGMP) Fast Leave processing. The no form of the command disables CGMP Fast Leave processing.
  cgmp leave-processing
  no cgmp leave-processing
  Syntax Description
  This command has no arguments or keywords.
  Default
  The default configuration is disabled.
  Command Mode
  Global configuration
  Usage Guidelines
  Fast Leave processing optimizes the use of network bandwidth by reducing the delay between members of a multicast group leaving the group and the actual pruning of multicast traffic to that segment.
  This command is available only if CGMP is enabled. Otherwise, the command is not recognized.
  Example
  This command enables CGMP Fast Leave processing.
  hostname(config)# cgmp leave-processing
  Related Commands
  cgmp
  cgmp (hold-time)
  cgmp (remove)
  clear (cgmp)
  show (cgmp)
  cgmp (remove)
  Use the cgmp remove global configuration command to remove an address that has been added to the system by Cisco Group Management Protocol (CGMP) activity.
  cgmp remove mac-address
  Syntax Description
  mac-address MAC address.
  
  Default
  None
  Command Mode
  Global configuration
  Example
  This example shows how to remove the address 0100.5e00.0203 from the system.
  hostname(config)# cgmp remove 0100.5e00.0203
  Related Commands
  cgmp
  cgmp (hold-time)
  cgmp (leave-processing)
  clear (cgmp)
  show (cgmp)
  cgmp (reserved)
  Use the cgmp reserved global configuration command to permit Cisco Group Management Protocol (CGMP) reserved addresses (from 0100.5E00.0000 to 0100.5E00.00FF) to join as Group Destination Addresses. The no form of the command excludes these reserved addresses.
  cgmp reserved
  no cgmp reserved
  Syntax Description
  This command has no arguments or keywords.
  Default
  Permitted
  Command Mode
  Global configuration
  Example
  This command shows how to exclude reserved addresses from the Group Destination Address for compatibility with Catalyst 5000 series switches.
  hostname# no cgmp reserved
  Related Commands
  cgmp
  cgmp (hold-time)
  cgmp (remove)
  cgmp (leave-processing)
  clear (cgmp)
  show (cgmp)
  clear (cgmp)
  Use the clear cgmp privileged Exec command to remove the specified multicast group or router.
  clear cgmp [vlan vlan-id] [group [address] | router [address]]
  Syntax Description
  vlan vlan-id A VLAN ID number from 1 to 1005.
  group One or more multicast groups.
  router One or more routers.
  address MAC address of specific multicast group or router.
  
  Default
  None
  Command Mode
  Privileged Exec
  Usage Guidelines
  If the vlan option is specified with the group or router option, only multicast groups or routers in the specified VLAN are removed. If the vlan option is specified without group or router option, all multicast groups and routers are removed from the specified VLAN.
  Example
  This command removes all multicast groups and routers from VLAN 1.
  hostname# clear cgmp vlan 1
  
  This command removes all multicast groups.
  hostname# clear cgmp group
  
  This command removes all multicast routers.
  hostname# clear cgmp router
  
  This command removes the multicast group with the MAC address 0100.5e00.0128.
  hostname# clear cgmp group 0100.5e00.0128
  
  This command removes the multicast router with the MAC address 00e0.1e68.7751.
  hostname# clear cgmp router 00e0.1e68.7751
  Related Commands
  cgmp
  cgmp (hold-time)
  cgmp (leave-processing)
  cgmp (remove)
  show (cgmp)
  clear (dns-cache)
  Use the clear dns-cache privileged Exec command to remove all cached Domain Name System (DNS) entries from the switch.
  clear dns-cache
  Syntax Description
  This command has no arguments or keywords.
  Command Mode
  Privileged Exec
  Example
  This example shows how to clear all DNS entries for the switch.
  hostname# clear dns-cache
  Related Commands
  ip (domain-name)
  ip (name-server)
  clear (counters)
  Use the clear counters privileged Exec command to reset the interface counters for a switched port interface to zero.
  clear counters [type module/port]
  Syntax Description
  type Interface type: ethernet, fastethernet, fddi, atm, or port-channel.
  module Module interface number:0 for fixed1 or A for module A2 or B for module B
  port Port identification number or name:1 to 25 Ethernet (fixed)26, 27 Fast Ethernet (fixed)Port channel
  
  Command Mode
  Privileged Exec
  Usage Guidelines
  If you do not specify type module/port, the switch clears the counters for all interfaces.
  Example
  This example shows how to clear counters for the Ethernet port 1.
  hostname# clear counters ethernet 0/1
  Related Commands
  interface
  show (interfaces)
  clear (mac-address-table)
  Use the clear mac-address-table privileged Exec command to remove a specified address (or set of addresses) from the MAC address table.
  clear mac-address-table [dynamic | restricted static | permanent] [address mac-address]
  [interface type module/port]
  Syntax Description
  dynamic Clears only dynamic addresses.
  restricted static Clears only restricted static addresses.
  permanent Clears only permanent addresses.
  address Clears only a specified address.
  mac-address Target MAC address.
  interface Clears all addresses for an interface.
  type Interface type: ethernet, fastethernet, fddi, atm, or port channel.
  module The module interface number.0 for fixed1 or A for module A2 or B for module B
  port Port interface number ranging from 1 to 28:1 to 25 Ethernet (fixed)26, 27 Fast Ethernet (fixed)Port channel
  
  Default
  The dynamic addresses are cleared.
  Command Mode
  Privileged Exec
  Usage Guidelines
  If clear mac-address-table is invoked with no options, all dynamic addresses are removed. If you specify an address but do not specify an interface, the address is deleted from all interfaces. If you specify an interface but do not specify an address, all addresses on the specified interface are removed.
  If a targeted address is not present in the MAC forwarding table, the following error message appears:
  MAC address not found
  Example
  This example shows how to clear all dynamic addresses in the MAC forwarding table.
  hostname# clear mac-address-table
  
  This command clears the permanent address 0040.C80A.2F07 on Ethernet port 1.
  hostname# clear mac-address-table permanent address 0040.C80A.2F07 interface ether 0/1
  Related Commands
  mac-address-table (aging-time)
  mac-address-table (permanent)
  mac-address-table (restricted static)
  show (mac-address-table)
  show (mac-address-table security)
  clear (uplink-fast statistics)
  Use the clear uplink-fast statistics privileged Exec command to reset all Uplink Fast counter statistics to zero.
  clear uplink-fast statistics
  Syntax Description
  This command has no additional arguments or keywords.
  Command Mode
  Privileged Exec
  Usage Guidelines
  This command is not functional when bridge groups are enabled.
  Example
  This example shows how to reset all Uplink Fast counters to zero:
  hostname# clear uplink-fast statistics
  Related Commands
  uplink-fast
  show (uplink-fast)
  show (uplink-fast statistics)
  clear (vtp statistics)
  Use the clear vtp statistics privileged Exec command to reset all VLAN Trunk Protocol (VTP) statistics counters to zero.
  clear vtp statistics
  Syntax Description
  This command has no additional arguments or keywords.
  Command Mode
  Privileged Exec
  Usage Guidelines
  This command is not functional when bridge groups are enabled.
  Example
  This example shows how to reset all VTP statistics counters to zero.
  hostname# clear vtp statistics
  Related Commands
  delete (vtp)
  show (vtp)
  show (vtp statistics)
  vtp
  vtp trunk pruning-disable
  cluster
  The cluster global configuration command is used under certain conditions to add the switch back into a cluster. The no cluster command removes the switch from its cluster.
  cluster commander-address
  no cluster commander-address
  Syntax Description
  commander_address MAC address of commander switch.
  
  Command Mode
  Global configuration
  Usage Guidelines
  Caution We strongly recommend that you use a command switch management interface to add or remove Catalyst 1900 series or Catalyst 2820 series switches from a cluster. The cluster commander-address command is primarily for debugging and recovery purposes.If you use the no cluster command to remove a Catalyst 1900 series or Catalyst 2820 series switch, you cannot add the switch back into the cluster until you use one of the command switch management interfaces to remove, and then add the switch.
  To learn more about member switches in a cluster, refer to the Catalyst 1900 Series Installation and Configuration Guide or the Catalyst 2820 Series Installation and Configuration Guide.
  Example
  This example shows how to remove the switch from a cluster.
  hostname(config)# no cluster commander-address
  
  This example shows how to add the switch back into the cluster managed by command switch 00D0.5868.F580 after it has been removed and added again using one of the command switch management interfaces.
  hostname(config)# cluster 00D0.5868.F580
  Related Commands
  show cluster
  configure
  Use the configure privileged Exec command to enter the global configuration mode. Use the optional terminal keyword to specify a specific terminal.
  config [terminal]
  Syntax Description
  terminal Name of target terminal.
  
  Command Mode
  Privileged Exec
  Example
  This example shows how to enter global configuration mode.
  hostname# configure
  hostname(config)#
  
  This example shows how to enter global configuration mode from terminal t.
  hostname# configure t
  Related Commands
  disable
  enable
  end
  exit
  interface
  line console
  copy (nvram tftp)
  Use the copy (nvram tftp) privileged Exec command to upload the running nondefault configuration to a Trivial File Transfer Protocol (TFTP) server host and the destination file dst_file.
  copy nvram tftp://host/dst_file
  Syntax Description
  //host/dst_file Target host and destination file where host is an IP address or a hostname.
  
  Command Mode
  Privileged Exec
  Usage Guidelines
  Error messages appear in the following situations:
  ?The host is unreachable (using existing time-out implementation).
  ?The host terminates the TFTP session.
  ?The host specified cannot be resolved through DNS.
  If other download or upload operations (firmware, configuration, web pages) are in progress, the following error message appears:
  Other downloads or uploads in progress. Please wait until existing download or upload is completed.
  Example
  This example shows how to use TFTP to upload the switch NVRAM configuration to the host spaniel using destination file matilda.cfg.
  hostname# copy nvram tftp://spaniel/matilda.cfg
  
  Configuration upload is successfully completed
  
  If the upload fails, the following message displays:
  Error: Configuration upload operation failed
  Related Commands
  copy (tftp)
  service (config)
  show (running-config)
  show (version)
  tftp (accept)
  tftp (server)
  copy (tftp)
  Use the copy tftp privileged Exec command to download a configuration or operation code file from the Trivial File Transfer Protocol (TFTP) server.
  copy tftp://host/src_file {opcode [type module] | nvram}
  Syntax Description
  //host/src_file Host and source file where host is an IP address or hostname. Source filename can be up to 80 characters.
  opcode Download new operation code.
  type Interface type. The valid values are fddi and atm.
  module Interface number: 1 or A for module A, and 2 or B for module B.
  nvram Download a configuration file into NVRAM.
  
  Command Mode
  Privileged Exec
  Usage Guidelines
  You must specify type and module if the download is for a module.
  Downloaded configuration files are executed immediately. If the switch is connected to a console, any errors during execution will generate an error message. The switch attempts to execute all commands, irrespective of failures.
  When downloading an operation code file, the entire system (including other CLI sessions) is inactive for about 30 seconds after the file is retrieved.
  Error messages appear in the following situations:
  ?The operation code file is not in the correct format.
  ?The host is unreachable (using existing time-out implementation).
  ?The host aborts the TFTP session.
  ?The host specified cannot be resolved through DNS.
  ?The module specified does not have firmware or a configuration that can be downloaded.
  If other download or upload operations (firmware, configuration, web pages) are in progress, the following message appears:
  Other downloads or uploads in progress. Please wait until existing download or upload is completed.
  Examples
  This example shows how to download new system operational code op.bin from host spaniel.
  hostname# copy tftp://spaniel/op.bin opcode
  
  This example shows how to download new FDDI operational code fddi.bin from host spaniel to the FDDI module in slot A.
  hostname# copy tftp://spaniel/fddi.bin opcode fddi A
  
  TFTP successfully downloaded operational code
  
  This example shows how to download configuration file matilda.cfg to NVRAM from host spaniel.
  hostname# copy tftp://spaniel/matilda.cfg nvram
  
  TFTP successfully downloaded configuration file
  
  If the download fails, the following message displays:
  Error: TFTP failed to download the configuration file
  Related Commands
  copy (nvram tftp)
  service (config)
  show (running-config)
  show (version)
  tftp (accept)
  tftp (server)
  copy (xmodem)
  Use the copy xmodem privileged Exec command to download an operation code or firmware file by using the XMODEM protocol.
  copy xmodem: src_file opcode [type module]
  Syntax Description
  src_file Firmware filename.
  opcode Download new operation code.
  type Interface type. Valid values are fddi and atm.
  module Interface number: 1 or A for module 1, 2 or B for module 2.
  
  Default
  If you specify type and module, the file copies the code or file to the specified module. When type and module are not specified, the file copies them to the switch firmware.
  Command Mode
  Privileged Exec
  Usage Guidelines
  You cannot enter any new information or commands until the download is completed. After downloading operation code file, the entire system (including other CLI sessions) is inactive for about 30 seconds.
  Example
  This example shows how to download the operational code file.
  hostname# copy xmodemp_code.bin opcode
  
  This shows how to download new FDDI operational code fddi.bin to module slot A.
  hostname# copy xmodem:fddi.bin opcode fddi A
  Related Commands
  copy (tftp)
  copy (xmodem)
  show (running-config)
  show (version)
  databits
  Use the databits line-configuration command to set the data bits per character for a port.
  databits [7 | 8]
  Syntax Description
  7 or 8 Number of data bits per character.
  
  Default
  8 data bits per character.
  Command Mode
  Line configuration
  Example
  This example shows how to set the number of data bits per character to 7.
  hostname(config-line)# databits 7
  Related Commands
  autobaud
  line console
  modem (dialin)
  parity
  show (line)
  show (terminal)
  speed
  stopbits
  terminal
  delete (nvram)
  Use the delete nvram privileged Exec command to reset the system or module configuration to factory defaults.
  delete nvram [type module]
  Syntax Description
  type Interface type. Valid values are fddi and atm.
  module Module interface number: 1 or A for module A, and 2 or B for module B.
  
  Default
  The system or module is reset to factory defaults.
  Command Mode
  Privileged Exec
  Usage Guidelines
  
  Note If you reset a Catalyst 2820 switch by using the delete nvram command, you reset both the system and the module. However, resetting the switch to factory defaults does not reset module arguments stored in the module NVRAM.
  
  Examples
  This example shows how to reset system configuration to factory defaults.
  hostname(config)# delete nvram
  
  This command resets the switch with factory defaults. All parameters will revert to their default factory settings. All static system and dynamic addresses will be removed.
  Reset system with factory defaults, [y]es or [n]o?
  
  Press Y or N to proceed.
  This example shows how to reset the ATM module in slot A to factory defaults.
  hostname(config)# delete nvram atm 1
  
  This command resets the module and restores all settings to factory defaults.
  The module is deinstalled until it successfully completes its self tests.
  
  Reset module with factory defaults, [Y]es or [N]o?
  
  Press Y or N to proceed.
  Related Commands
  copy (tftp)
  reload
  delete (vtp)
  Use the delete vtp privileged Exec command to set the system VLAN Trunk Protocol (VTP) configuration back to factory defaults.
  delete vtp
  Syntax Description
  This command has no additional arguments or keywords.
  Command Mode
  Privileged Exec
  Usage Guidelines
  Resetting the system VTP configuration also resets the system. This command first prompts the user to confirm:
  This command resets the switch VTP arguments to factory defaults. All other arguments will be unchanged.
  Reset system VTP arguments to factory defaults, [y]es or [n]o?
  
  Press Y or N to proceed.
  Example
  This example shows how to reset system VTP configuration to factory defaults.
  hostname# delete vtp
  Related Commands
  clear (vtp statistics)
  show (vtp)
  show (vtp statistics)
  vtp
  vtp trunk pruning-disable
  description
  Use the description interface configuration command to describe or name an interface. Use the no description command to remove a description from an interface.
  description name-string
  no description
  Syntax Description
  name-string A text description between 1 and 80 alphanumeric characters.
  
  Default
  This command has no default value.
  Command Mode
  Interface configuration
  Usage Guidelines
  To use the description command, you must first identify the interface you want while working in global configuration mode. Enter the interface command with an interface identifier to enter interface configuration mode, where you can then enter a description.
  If you want to enter a description with spaces between characters, you must enclose the string in quotation marks (see "Paul's machine" example, below)
  Example
  This example shows how to give the name Hal to Ethernet port 1.
  hostname(config)# interface ether 0/1
  hostname(config-if)# description Hal
  
  This example shows how to give the name Paul's machine to ATM module 1.
  hostname(config)# interface atm A
  hostname(config-if)# description "Paul's machine"
  
  This example shows how to give the description server1 to port 1 on ATM module 1.
  hostname(config)# interface atm A
  hostname(config-if)# description server1
  Related Commands
  interface
  show cdp (interface)
  show (interfaces)
  disable
  Use the disable privileged Exec command to exit the privileged access level and enter user levels.
  disable
  Syntax Description
  This command has no arguments or keywords.
  Command Mode
  Privileged Exec
  Example
  This example shows how to exit privileged Exec mode and change to user Exec mode.
  hostname# disable
  Related Command
  configure
  enable
  end
  exit
  interface
  line console
  duplex
  Use the duplex interface configuration command to enable duplex mode for an interface.
  duplex {auto | full | full-flow-control | half}
  Syntax Description
  auto Auto-negotiation of duplex mode.
  full Full-duplex mode.
  full-flow-control Force full-duplex mode with flow control.
  half Half-duplex mode.
  
  Defaults
  For 100-Mbps TX ports: duplex auto.
  For all other ports that support half- and full-duplex: duplex half.
  Command Mode
  Interface configuration
  Usage Guidelines
  Use the auto argument only for fixed Fast Ethernet TX ports. In auto-negotiation mode, the switch attempts to negotiate full-duplex connectivity with the connecting device. If negotiation is successful, the port operates in full-duplex mode. If the connecting device is unable to operate in full-duplex, the port operates in half-duplex. This process is repeated whenever there is a change in link status.
  Example
  This example shows how to set the port to full-duplex mode.
  hostname(config-if)# duplex full
  Related Commands
  interface
  show (interfaces)
  back-pressure
  ecc
  Use the ecc global configuration command to enable Enhanced Congestion Control (ECC). This command allows frames to be discarded early when a port becomes congested, which limits the number of frames queued on a port. Use the no ecc command to disable congestion control.
  ecc {10M | A | B} {adaptive | moderate-aggressive | aggressive}
  no ecc [10M | A | B]
  Syntax Description
  10M Congestion control for 10-Mbps ports.
  A Congestion control for port A. For single Fast Ethernet fixed and modular ports only.
  B Congestion control for port B. For single Fast Ethernet fixed and modular ports only.
  adaptive Adaptive congestion control.
  moderate-aggressive Moderately aggressive congestion control.
  aggressive Aggressive congestion control.
  
  Default
  Enhanced congestion control is disabled.
  Command Mode
  Global configuration
  Examples
  This example shows how to set enhanced congestion control for the 10-Mbps Ethernet ports to adaptive.
  hostname(config)# ecc 10m adaptive
  
  This example shows how to set enhanced congestion control for Fast Ethernet port A to aggressive.
  hostname(config)# ecc A aggressive
  Related Command
  show (port system)
  enable
  Use the enable Exec command to enter privileged Exec mode.
  enable [access-level]
  Syntax Description
  access-level 1 through 14 (user Exec level) or 15 (privileged Exec level).
  
  Default
  The access-level default for initial login is 1. The default access level after login is 15.
  Command Mode
  User and privileged Exec
  Usage Guidelines
  If a password is configured, you are prompted for the password:
  Password:
  
  You are allowed three attempts to provide the correct password. The same prompt is repeated until you enter the correct password or you exceed the maximum number of attempts. If the password fails after the maximum attempts, the following error message appears:
  Bad password.
  Example
  This example shows you how to move from user Exec mode access to privileged Exec mode access.
  hostname> enable
  hostname#
  Related Command
  configure
  disable
  end
  exit
  interface
  line console
  enable (password)
  Use the enable password global configuration command to set unencrypted user Exec or privileged Exec passwords. Use the no enable password command to clear the password.
  enable password level <1-15>
  no enable password level level
  Syntax Description
  level <1-15> Level for which the password applies:1-14 user Exec privileges.15 privileged Exec privileges.
  password A noncase-sensitive string of between 4 and 8 characters, spaces, and punctuation (except double quotes). Password strings with blank spaces must be enclosed in double quotes.
  
  Default
  No default password.
  Command Mode
  Global configuration
  Usage Guidelines
  The level argument must be specified.
  For more information about assigning passwords of various levels and encryption modes, see "Understanding Command Modes" in "Overview."
  Examples
  This example shows how to set an unencrypted privileged Exec password to WILLOW 6.
  hostname(config)# enable password level 15 "WiLLoW 6"
  
  Both of these examples show how to set an unencrypted user Exec password to MAY DAY.
  hostname(config)# enable password level 1 "May Day"
  hostname(config)# enable password level 8 "may day"
  Related Commands
  enable (secret)
  enable (use-tacacs)
  enable (secret)
  Use the enable secret global configuration command to set encrypted user Exec or privileged Exec passwords. Use the no enable secret command to clear the password.
  enable secret [level <1-15>] [0 | 5 ]
  no enable secret [level <1-15>]
  Syntax Description
  level <1-15> Level for which the password applies:1-14 user Exec privileges.15 privileged Exec privileges.
  0 Specifies an unencrypted password follows.
  5 Specifies an encrypted password follows.
  password A case-sensitive string of between 1 and 25 characters, spaces, and punctuation.
  
  Default
  Privilege level 15, unencrypted.
  No default password.
  Command Mode
  Global configuration
  Usage Guidelines
  
  Note Encrypted passwords are typically used only in configuration files generated by the switch.
  
  The level argument must be used to specify any level 1 through 14 encrypted password. The level argument is optional when specifying a default level 15 encrypted password.
  Although levels 2 to 14 are accepted, levels 1 to 14 map to user-level password (level 1). For more information about assigning passwords of various levels and encryption modes, see "Understanding Command Modes" in the "Overview" chapter.
  If you enter a password that begins with a number followed by a space, an error message appears:
  hostname(config)# enable secret level 1 9 lives
  Invalid encryption type: 9
  Examples
  The following examples show different ways to set an unencrypted privileged Exec password to Pass&WoRd-87.
  hostname(config)# enable secret Pass&WoRd-87
  hostname(config)# enable secret 0 Pass&WoRd-87
  hostname(config)# enable secret level 15 Pass&WoRd-87
  hostname(config)# enable secret level 15 0 Pass&WoRd-87
  
  The following examples show two ways to set an encrypted privileged Exec password to grandkey.
  hostname(config)# enable secret 5 $1$8KiD$mmxIOicclo6PgXTq97Rfb/
  hostname(config)# enable secret level 15 5 $1$8KiD$mmxIOicclo6PgXTq97Rfb/
  
  The following examples show two ways to set an unencrypted user Exec password to Forescore & 7 years ago.
  hostname(config)# enable secret level 1 Forescore & 7 years ago
  hostname(config)# enable secret level 12 0 Forescore & 7 years ago
  
  The following example shows how to set an encrypted user Exec password to grandkey.
  hostname(config)# enable secret level 14 5 $1$8KiD$mmxIOicclo6PgXTq97Rfb/
  Related Commands
  enable (password)
  enable (use-tacacs)
  enable (use-tacacs)
  Use the enable use-tacacs global configuration command to use the Cisco Terminal Access Controller Access Control System Plus (TACACS+) for authentication of all switch passwords from a central authentication server. Use the no enable use-tacacs command to disable central authentication of switch passwords.
  enable use-tacacs
  no enable use-tacacs
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  Disabled.
  Command Mode
  Global configuration
  Usage Guidelines
  If you do not use TACACS+ to authenticate passwords, local authentication is enabled.
  Example
  This example shows how to use TACACS+ for central authentication of switch passwords.
  hostname(config)# enable use-tacacs
  Related Commands
  enable (password)
  enable (secret)
  login (tacacs)
  show (tacacs)
  tacacs-server (last-resort)
  end
  Use the end command from global configuration mode (config), interface configuration mode (config-if), and line configuration mode (config-line) to exit the current mode and enter privileged Exec mode.
  end
  Syntax Description
  This command has no arguments or keywords.
  Default
  None
  Command Mode
  All configuration modes.
  Usage Guidelines
  To exit the system and terminate the console or telnet session, use the exit command.
  Example
  This example shows how to exit the global configuration mode and enter privileged Exec mode.
  hostname(config)# end
  hostname#
  Related Commands
  configure
  disable
  enable
  exit
  interface
  line console
  exit
  Use the exit configuration command to exit the system or current configuration mode.
  exit
  Syntax Description
  This command has no arguments or keywords.
  Command Mode
  All configuration and Exec modes.
  Usage Guidelines
  If the current mode is privileged or user Exec, this command exits the system and terminates the console or Telnet session. If the current mode is global configuration, this commands sets the mode to privileged Exec. If the current mode is other than global configuration, this command sets the mode to global configuration.
  Example
  This example shows how to exit from global configuration mode and enter privileged Exec mode:
  hostname(config)# exit
  hostname#
  
  This example shows how to exit from interface configuration mode and enter global configuration mode:
  hostname(config-if)# exit
  hostname(config)#
  Related Commands
  configure
  disable
  enable
  end
  interface
  line console
  fddi (authorization)
  Use the fddi authorization interface configuration command to enable authorization checking for the station management (SMT) entity. Use the no fddi authorization command to disable authorization checking.
  fddi authorization
  no fddi authorization
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  FDDI authorization is disabled.
  Command Mode
  Interface configuration
  Usage Guidelines
  When authorization string checking is enabled, the FDDI module uses the current authorization string to verify SMT requests from remote stations. This command is only valid within FDDI module interface-configuration mode.
  Example
  This example shows how to enable authorization string checking.
  hostname(config-if)# fddi authorization
  
  This example shows how to disable authorization string checking.
  hostname(config-if)# no fddi authorization
  Related Commands
  fddi (auth-string)
  fddi (notify-timer)
  fddi (novell-snap-translation)
  fddi (unmatched-snap-translation)
  interface
  show (interfaces)
  fddi (auth-string)
  Use the fddi auth-string interface configuration command to assign a new authorization string value used in the verification of station management (SMT) requests. Use the no fddi auth-string command to clear the existing authorization string.
  fddi auth-string string
  no fddi auth-string
  Syntax Description
  string A string of 4 to 80 alphanumeric characters entered in multiples of 4 characters.
  
  Default
  No FDDI authorization string is set.
  Command Mode
  Interface configuration
  Usage Guidelines
  This command is only valid within FDDI module interface-configuration mode.
  
  Note You must enter an authorization string with a number of characters (including punctuation and numbers) that is divisible by 4.
  
  Example
  This example shows how to assign the authorization string value check_it (8 characters).
  hostname(config-if)# fddi auth-string check_it
  Related Commands
  fddi (authorization)
  fddi (notify-timer)
  fddi (novell-snap-translation)
  fddi (unmatched-snap-translation)
  interface
  show (interfaces)
  fddi (notify-timer)
  Use the fddi notify-timer interface configuration command to assign a new timer value for the Neighbor Notification Protocol. Use the no fddi notify-timer command to set the timer value to module defaults.
  fddi notify-timer seconds
  no fddi notify-timer
  Syntax Description
  seconds A number between 2 and 30 seconds.
  
  Default
  30 seconds.
  Command Mode
  Interface configuration.
  Usage Guidelines
  This command is only valid within FDDI module interface-configuration mode.
  Example
  This example shows how to set the notify timer to 15 seconds.
  hostname(config-if)# fddi notify-timer 15
  Related Commands
  fddi (authorization)
  fddi (auth-string)
  fddi (novell-snap-translation)
  fddi (unmatched-snap-translation)
  interface
  show (interfaces)
  fddi (novell-snap-translation)
  Use the fddi novell-snap-translation interface configuration command to define how to translate Novell Subnetwork Access Protocol (SNAP) FDDI frames from FDDI ring to Ethernet. Use the no no fddi novell-snap-translation command to set the translate value to module defaults.
  fddi novell-snap-translation {automatic | ethernet-8023 | ethernet-snap | ethernet-II | drop}
  no fddi novell-snap-translation
  Syntax Description
  automatic Automatic packet recognition and translation for IPX networks of FDDI modules.
  drop Translate frames using Drop protocol.
  ethernet-8023 Translate frames using Ethernet 802.3 protocol.
  ethernet-II Translate frames using Ethernet II protocol.
  ethernet-snap Translate frames using Ethernet SNAP.
  
  Default
  Automatic packet recognition is enabled.
  Command Mode
  Interface configuration
  Usage Guidelines
  This command is only valid within FDDI module interface-configuration mode.
  Example
  This example shows how to enable automatic packet recognition and translation for IPX networks of FDDI modules.
  hostname(config-if)# fddi novell-snap-translation automatic
  Related Commands
  fddi (authorization)
  fddi (auth-string)
  fddi (notify-timer)
  fddi (unmatched-snap-translation)
  interface
  show (interfaces)
  fddi (unmatched-snap-translation)
  Use the fddi unmatched-snap-translation interface configuration command to select which FDDI-to-Ethernet translation protocol to use for packets whose destinations cannot be determined from the Novell Subnetwork Access Protocol (SNAP) translation table.
  fddi unmatched-snap-translation {all | ethernet-8023 | ethernet-snap | ethernet-II | drop}
  no fddi unmatched-snap-translation
  Syntax Description
  all Ethernet 802.3, Ethernet SNAP, and Ethernet II are all used.
  drop Translate frames using Drop protocol.
  ethernet-8023 Translate frames using Ethernet 802.3 protocol.
  ethernet-II Translate frames using Ethernet SNAP.
  ethernet-snap Translate frames using Ethernet II protocol.
  
  Default
  All translation protocols are enabled.
  Command Mode
  Interface configuration
  Usage Guidelines
  This command is valid only when you select automatic as the SNAP translation format and you enter the command within FDDI module interface-configuration mode.
  Example
  This example shows how to select FDDI-to-Ethernet 802.3 translation for FDDI packets with unmatched destination addresses.
  hostname(config-if)# fddi unmatched-snap-translation ether802.3
  Related Commands
  fddi (authorization)
  fddi (auth-string)
  fddi (notify-timer)
  fddi (novell-snap-translation)
  interface
  show (interfaces)
  hostname
  Use the hostname global configuration command to set the system name. Use the no hostname command to clear the name.
  hostname name
  no hostname
  Syntax Description
  name System name between 1 and 255 alphanumeric characters.
  
  Default
  There is no default for this command.
  Command Mode
  Global configuration
  Example
  This example shows how to set the system name to the string Zorro.
  2820(config)# hostname Zorro
  Zorro(config)#
  Related Command
  show (snmp hostname)
  interface
  Use the interface global configuration command to choose an interface type and to enter interface configuration mode.
  interface type module/port
  Syntax Description
  type Interface type: ethernet, fastethernet, fddi, atm, and port-channel.
  module Module interface number:0 for fixed1 or A for module A2 or B for module B
  port Port interface number ranging from 1 to 27:1 to 25 Ethernet (fixed)26, 27 Fast Ethernet (fixed)1 to 4 Fast Ethernet (4-port Fast Ethernet repeater module)1 to 8 Fast Ethernet (8-port Fast Ethernet repeater module)
  
  Default
  No default interface.
  Command Mode
  Global configuration
  Example
  This example shows how to enable configuration on Ethernet port 1.
  hostname(config)# interface ethernet 0/1
  
  This example shows how to enable configuration on ATM module 1.
  hostname(config)# interface atm 1
  Related Commands
  configure
  disable
  enable
  end
  exit
  line console
  ip (address)
  Use the ip address global configuration command to configure the IP address and subnet mask. Use the no ip address command to set the IP address and subnet mask to default values.
  ip address ipaddress mask
  no ip address
  Syntax Description
  ipaddress IP address.
  mask Subnet mask.
  
  Default
  IP address and subnet mask both have the value 0.0.0.0.
  Command Mode
  Global configuration
  Example
  This example shows how to set the device IP address to 172.20.128.126 and the subnet mask to 255.255.255.0 on the specified interface.
  hostname(config)# ip address 172.20.128.126 255.255.255.0
  Related Commands
  ip (default-gateway)
  ip (domain-name)
  ip (http port)
  ip (http server)
  ip (mgmt-vlan)
  ip (name-server)
  show (ip)
  ip (default-gateway)
  Use the ip default-gateway global configuration command to configure the default gateway. Use the no ip default-gateway command to delete a configured default gateway and to set the gateway address to the default value.
  ip default-gateway ip-address
  no ip default-gateway
  Syntax Description
  ip-address Gateway IP address.
  
  Default
  Gateway address has the value 0.0.0.0.
  Command Mode
  Global configuration
  Example
  This example shows how to set the default gateway address to 172.20.128.126.
  hostname(config)# ip default-gateway 172.20.128.126
  Related Commands
  ip (address)
  ip (domain-name)
  ip (http port)
  ip (http server)
  ip (mgmt-vlan)
  ip (name-server)
  show (ip)
  ip (domain-name)
  Use the ip domain-name global configuration command to configure a domain name. Use the no ip domain-name command to clear any configured domain name.
  ip domain-name domain-name
  no ip domain-name
  Syntax Description
  domain-name A string between 1 and 62 characters that specifies the domain name.
  
  Default
  No domain name is configured.
  Command Mode
  Global configuration
  Example
  This example shows how to configure the domain name of the switch to your_company.com.
  hostname(config)# ip domain-name your_company.com
  Related Commands
  ip (address)
  ip (default-gateway)
  ip (http port)
  ip (http server)
  ip (mgmt-vlan)
  ip (name-server)
  show (ip)
  ip (http port)
  Use the ip http port global configuration command to select a Transmmission Control Protocol (TCP) port on which the Hypertext Transfer Protocol (HTTP) server accepts connections. Use the no ip http port command to select the default TCP port.
  ip http port port-number
  no ip http port
  Syntax Description
  port-number TCP port number between 0 and 65535.
  
  Default
  TCP port 80.
  Command Mode
  Global configuration
  Example
  This example shows how to set the server to listen on TCP port 8080 for HTTP connections. With this (nondefault) setting, you must instruct your browser to connect to port 8080 rather than 80.
  hostname(config)# ip http port 8080
  Related Commands
  ip (address)
  ip (default-gateway)
  ip (domain-name)
  ip (http server)
  ip (mgmt-vlan)
  ip (name-server)
  show (ip)
  ip (http server)
  Use the ip http server global configuration command to enable Hypertext Transfer Protocol (HTTP) server functions. Use the no ip http server command to disable HTTP server functions.
  ip http server
  no ip http server
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  HTTP server functions are enabled.
  Command Mode
  Global configuration
  Example
  This example shows how to disable HTTP server functions.
  hostname(config)# no ip http server
  Related Command
  ip (address)
  ip (default-gateway)
  ip (http port)
  ip (mgmt-vlan)
  ip (name-server)
  show (ip)
  ip (mgmt-vlan)
  Use the ip mgmt-vlan global configuration command to configure a particular VLAN as the management VLAN (the VLAN from which IP packets are accepted and processed). Use the no ip mgmt-vlan command to set the default value as the management VLAN.
  ip mgmt-vlan vlan-number
  no ip mgmt-vlan
  Syntax Description
  vlan-number VLAN number between 1 and 1005.
  
  Default
  VLAN 1 is the management VLAN.
  Command Mode
  Global configuration
  Usage Guidelines
  This command is only available when VLANs are enabled. IP traffic is received and processed only from the management VLAN.
  Example
  This example shows how to set VLAN 2 as the management VLAN.
  hostname(config)# ip mgmt-vlan 2
  Related Commands
  ip (address)
  ip (default-gateway)
  ip (domain-name)
  ip (http port)
  ip (http server)
  ip (name-server)
  show (ip)
  ip (name-server)
  Use the ip name-server global configuration command to configure a domain name system (DNS) server. Use the no ip name-server command to delete any configured DNS server.
  ip name-server name-server
  no ip name-server name-server
  Syntax Description
  name-server The IP address of the DNS server.
  
  Default
  No name server address is configured.
  Command Mode
  Global configuration
  Usage Guidelines
  No more than two name-server addresses at a time can be specified for the switch. If two name servers are already specified and the user tries to specify a third, an error message appears. To add a new name server when two are already specified, delete one by using the no form of the command before adding the new server information.
  Example
  This example shows how to configure a server at IP address 172.20.128.126 as a name server for the switch.
  hostname(config)# ip name-server 172.20.128.126
  Related Commands
  ip (address)
  ip (default-gateway)
  ip (domain-name)
  ip (http port)
  ip (http server)
  ip (mgmt-vlan)
  show (ip)
  line console
  Use the line console global configuration command to change to line-configuration mode.
  line console
  Syntax Description
  This command has no additional arguments or keywords.
  Command Mode
  Global configuration
  Example
  This example shows how to change the command mode from global configuration to line configuration.
  hostname(config)# line console
  hostname(config-line)#
  Related Commands
  configure
  disable
  enable
  end
  exit
  interface
  login (tacacs)
  Use the login tacacs global configuration command to enable the Cisco Terminal Access Controller Access Control System Plus (TACACS+) for authenticating user logins. If login TACACS+ is enabled, the switch uses TACACS+ to authenticate all user logins through a console or Telnet interface. Use the no login tacacs command to disable TACACS+ authentication.
  login tacacs
  no login tacacs
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  Disabled
  Command Mode
  Global configuration
  Usage Guidelines
  Access to the web interface cannot be authenticated through TACACS+. When using the web interface, the authentication process defaults to the local switch password.
  Example
  This command shows how to enable TACACS+ for login authentication.
  hostname(config)# login tacacs
  Related Commands
  enable (use-tacacs)
  show (tacacs)
  tacacs-server (attempts)
  tacacs-server (directed-request)
  tacacs-server (host)
  tacacs-server (key)
  tacacs-server (last-resort)
  tacacs-server (timeout)
  mac-address-table (aging-time)
  Use the mac-address-table aging-time global configuration command to configure the length of time the switch keeps dynamic MAC addresses in memory before discarding. Use the no mac-address-table aging-time command to set the aging time to the default value.
  mac-address-table aging-time
  no mac-address-table aging-time
  Syntax Description
  seconds A value from 10 to 1000000 seconds.
  
  Default
  300 seconds
  Command Mode
  Global configuration
  Example
  This example shows how to specify a MAC address table aging time of 250000 seconds.
  hostname(config)# mac-address-table aging-time 250000
  Related Commands
  clear (mac-address-table)
  mac-address-table (restricted static)
  show (mac-address-table)
  mac-address-table (permanent)
  Use the mac-address-table permanent global configuration command to associate a permanent unicast or multicast MAC address with a particular switched port interface (specified by type and module/port). Use the no mac-address-table permanent command to delete a permanent MAC address.
  mac-address-table permanent mac-address type module/port
  no mac-address-table permanent mac-address type module/port
  Syntax Description
  mac-address MAC address.
  type Interface type: ethernet, fastethernet, fddi, atm, or port-channel.
  module Module interface number:0 for fixed1 or A for module A2 or B for module B
  port Port interface number ranging from 1 to 28:1 to 25 Ethernet (fixed)26, 27 Fast Ethernet (fixed)Port channel
  
  Default
  No permanent addresses are assigned.
  Command Mode
  Global configuration
  Usage Guidelines
  Use the arguments module/port only for switched ports and modules. When deleting an address by using the no mac-address-table permanent command, specify the interface on which the address resides.
  If you delete an address that is not present in the address table, the following error message appears:
  % Error: MAC address not found
  Example
  This example shows how to specify that packets with the multicast destination address 0140.C80A.2F07 should be forwarded on the Fast Ethernet interface 27.
  hostname(config)# mac-address-table permanent 0140.C80A.2F07 fastethernet 0/27
  Related Commands
  clear (mac-address-table)
  mac-address-table (aging-time)
  mac-address-table (restricted static)
  show (mac-address-table)
  mac-address-table (restricted static)
  Use the mac-address-table restricted static global configuration command to associate a restricted static address with a particular switched port interface (specified as type module/port). Use the no mac-address-table restricted static command to delete a restricted static address.
  mac-address-table restricted static mac-address type module/port src-if-list
  no mac-address-table restricted static mac-address type module/port
  Syntax Description
  mac-address MAC address.
  type Interface type: ethernet, fastethernet, fddi, atm, and port-channel.
  module Module interface number:0 for fixed1 or A for module 1 2 or B for module 2
  port Port interface number ranging from 1 to 28:1 to 25 Ethernet (fixed)26, 27 Fast Ethernet (fixed)Port channel
  src-if-list List of acceptable interfaces separated by spaces.
  
  Default
  No addresses are assigned.
  Command Mode
  Global configuration
  Usage Guidelines
  Use the arguments module/port only for switched ports and modules. Traffic to a restricted static address is only accepted from the interfaces specified in src-if-list.
  Example
  This example shows how to configure a packet with MAC address of 0040.C80A.2F07 to come in on either Ethernet interface 1 or Ethernet interface 2 and be forwarded to the Fast Ethernet interface 27.
  hostname(config)# mac-address-table restricted static 0040.C80A.2F07 fastethernet 0/27 ethernet 0/1 ethernet 0/2
  Related Commands
  clear (mac-address-table)
  mac-address-table (aging-time)
  mac-address-table (permanent)
  show (mac-address-table)
  menu
  Use the menu privileged Exec command to access the main menu console.
  menu
  Syntax Description
  This command has no arguments or keywords.
  Command Mode
  Privileged Exec
  Example
  This example shows how to display the main menu console.
  2820# menu
  Catalyst 2820 - Main Menu
  [C] Console Settings
  [S] System
  [N] Network Management
  [P] Port Configuration
  [A] Port Addressing
  [D] Port Statistics Detail
  [M] Monitoring
  [V] Virtual LAN
  [R] Multicast Registration
  [F] Firmware
  [I] RS-232 Interface
  [U] Usage Summaries
  [H] Help
  [K] Command Line
  
  [X] Exit Management Console
  
  Enter Selection:
  Related Commands
  None
  modem (dialin)
  Use the modem dialin line configuration command to enable auto-answer dial-in on a port. Use the no modem dialin command to disable dial-in.
  modem dialin
  no modem dialin
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  No modem dial-in is enabled.
  Command Mode
  Line configuration
  Example
  This example shows how to enable auto-answer dial-in.
  hostname(config-line)# modem dialin
  Related Commands
  autobaud
  databits
  line console
  modem (init-string)
  parity
  show (line)
  show (terminal)
  stopbits
  terminal
  modem (init-string)
  Use the modem init-string line-configuration command to configure the modem initialization string. Use the no modem init-string command to delete the modem initialization string.
  modem init-string init-string
  no modem init-string
  Syntax Description
  init-string The initalization string provided by your modem manufacturer.
  
  Default
  No initialization string is sent to the modem.
  Command Mode
  Line configuration
  Example
  This example shows how to configure a Hayes-compatible modem to reset to defaults and to set the verbosity level to terse.
  hostname(config-line)# modem init-string "Z V0"
  Usage Guidelines
  A default initialization string is provided by your modem manufacturer. Do not include the AT prefix or end-of-line suffix in your string.
  Related Commands
  autobaud
  databits
  line console
  modem (dialin)
  parity
  stopbits
  terminal
  monitor-port
  Use the monitor-port global configuration command to enable port monitoring. Use the no monitor-port command to disable monitoring.
  monitor-port
  no monitor-port
  Syntax Description
  This command has no arguments or keywords.
  Default
  No ports are monitored.
  Command Mode
  Global configuration
  Usage Guidelines
  Before you enable port monitoring, ensure that your capture list has one or more ports listed and a monitor port assigned. To add ports to the capture list, use the monitor-port monitored command. To assign a monitor port, use the monitor-port port command.
  Example
  This example shows how to enable port monitoring.
  hostname(config)# monitor-port
  Related Commands
  monitor-port (monitored)
  monitor-port (port)
  show (port monitor)
  monitor-port (monitored)
  Use the monitor-port monitored global configuration command to add ports to the monitoring capture list. Use the no monitor-port monitored command to delete ports from the list.
  monitor-port monitored [module/port]
  no monitor-port monitored [module/port]
  Syntax Description
  module Interface number from 0 to 2.
  port Port interface number ranging from 1 to 27:1 to 25 Ethernet (fixed)26, 27 Fast Ethernet (fixed)
  
  Default
  No ports are monitored.
  Command Mode
  Global configuration
  Usage Guidelines
  Use the arguments module/port for switched ports and modules only. If you do not specify the list of ports to add or delete in the no command form, all ports are deleted.
  Example
  This example shows how to add port 26 to the capture list.
  hostname(config)# monitor-port monitored 0/26
  
  This example shows how to delete port 2 from the capture list.
  hostname(config)# no monitor-port monitored 0/2
  
  This example shows how to delete all ports from the capture list.
  hostname(config)# no monitor-port monitored
  Related Commands
  monitor-port
  monitor-port (port)
  monitor-port (port)
  Use the monitor-port port global configuration command to specify the port to which monitored frames are sent. Use the no monitor-port port command to clear the monitor port.
  monitor-port port module/port
  no monitor-port port
  Syntax Description
  module Interface number between 0 and 2.
  port Port interface number ranging from 1 to 27:1 to 25 Ethernet (fixed)26, 27 Fast Ethernet (fixed)Port channel
  
  Default
  No monitor port is defined.
  Command Mode
  Global configuration
  Usage Guidelines
  Use the arguments module/port for switched ports and modules only. One or more ports must be listed in the port capture list for frame monitoring to occur.
  Example
  This example shows how to set port 1 to receive monitored frames.
  hostname(config)# monitor-port port 0/1
  Related Commands
  monitor-port
  monitor-port (monitored)
  multicast-store-and-forward
  Use the multicast-store-and-forward global configuration command to set multicast traffic forwarding to store-and-forward mode. Use the no multicast-store-and-forward command to set multicast traffic forwarding to the method specified by the switching-mode command.
  multicast-store-and-forward
  no multicast-store-and-forward
  Syntax Description
  This command has no arguments or keywords.
  Default
  Store-and-forward switching for multicast traffic is disabled.
  Command Mode
  Global configuration
  Example
  This example shows how to set the multicast traffic forwarding to store-and-forward.
  hostname(config)# multicast-store-and-forward
  
  This example shows how to set the multicast traffic forwarding to the method specified by the switching-mode command.
  hostname(config)# no multicast-store-and-forward
  Related Command
  switching-mode
  network-port
  Use the network-port global configuration command to set a network port. Use the no network-port command to clear a network port.
  network-port module/port
  no network-port
  Syntax Description
  module Module number from 0 to 2. Use the module argument only for switched modules.
  port Port number from 1 to 27. Use the port argument only for switched ports.
  
  Default
  A network port does not exist.
  Command Mode
  Global configuration
  Usage Guidelines
  When you configure a port as a network port, the following restrictions apply:
  ?It does not learn addresses.
  ?It is the only destination for unknown address packets.
  Example
  The following example shows how to set port 2 as a network port.
  hostname(config)# network-port 0/2
  Related Command
  show (port system)
  pagp-port-priority
  Use the pagp-port-priority interface configuration command to specify the Port Aggregation Protocol (PAgP) hot-standby priority for a single Fast Ethernet port.
  pagp-port-priority priority
  Syntax Description
  priority Number from 0 to 255.
  
  Default
  The default priority is 128.
  Command Mode
  Interface configuration
  Usage Guidelines
  This command has the following restrictions:
  ?It is valid only at the physical port interface level and applicable only to a single-switched, Fast Ethernet port.
  ?It is not functional when bridge groups are enabled.
  Example
  The following example shows how to set the PAgP priority for Fast Ethernet port A to 100:
  hostname(config)# interface fastethernet 0/26
  hostname(config-if)# pagp-port-priority 100
  Related Commands
  port-channel (mode)
  show (interfaces)
  port-channel (preserve-order)
  port-channel (template-port)
  parity
  Use the parity line-configuration command to set the parity of the port.
  parity {none | odd | even | mark | space}
  Syntax Description
  none No parity.
  odd Odd parity.
  even Even parity.
  mark Mark parity.
  space Space parity.
  
  Default
  The default is no parity.
  Command Mode
  Line configuration
  Example
  The following example shows how to set the parity of an Ethernet port to odd:
  hostname(config-line)# parity odd
  Related Commands
  autobaud
  databits
  line console
  modem (dialin)
  show (line)
  show (terminal)
  stopbits
  terminal
  password-thresh
  Use the password-thresh line configuration command to limit the number of incorrect password attempts to the switch. Use the no password-thresh command to allow unlimited incorrect password attempts.
  password-thresh attempts
  no password-thresh
  Syntax Description
  attempts A number from 1 to 65500.
  
  Default
  Three attempts
  Command Mode
  Line configuration
  Examples
  The following example shows how to limit the number of unsuccessful password attempts to 4.
  hostname(config-line)# password-thresh 4
  
  The following example shows how to remove password attempt limitations to the switch.
  hostname(config-line)# no password-thresh
  Related Commands
  show (terminal)
  silent-time
  time-out
  ping
  Use the ping user and privileged Exec command to send an ICMP echo message (ping) to the specified IP address or host name.
  ping {ip-address | hostname}
  Syntax Description
  ip-address Host IP address.
  hostname Host name.
  
  Default
  This command has no default value.
  Command Mode
  User and privileged Exec
  Usage Guidelines
  If you specify a host name rather than an IP address, the configured name server (which is configured by using the ip (name-server) command) resolves the host name to the IP address.
  Example
  The following example shows how to ping the host named penguins:
  > ping penguins
  Translating "penguins"...domain server (171.68.10.70) [OK]
  Type escape sequence to abort.
  Sending 5, 100-byte ICMP Echos to 171.69.71.25, timeout is 2 seconds:
  !!!!!
  Success rate is 100 percent (5/5), round-trip min/avg/max = 1/2/6 ms
  Related Commands
  ip (address)
  ip (default-gateway)
  ip (domain-name)
  ip (mgmt-vlan)
  ip (name-server)
  port-channel (mode)
  port-channel (preserve-order)
  port-channel (template-port)
  show (interfaces)
  show (ip)
  port (block)
  Use the port block interface configuration command to block the flooding of unknown multicast or unicast packets. Use the no port block command to enable the flooding of unknown multicast or unicast packets.
  port block {multicast | unicast}
  no port block {multicast | unicast}
  Syntax Description
  multicast Unknown multicast addresses.
  unicast Unknown unicast addresses.
  
  Default
  Flooding is enabled.
  Command Mode
  Interface configuration
  Examples
  The following example shows how to block the flooding of unknown multicast addresses:
  hostname(config-if)# port block multicast
  
  The following example shows how to allow the flooding of unknown unicast addresses:
  hostname(config-if)# no port block unicast
  Related Commands
  interface
  show (interfaces)
  show (port block)
  port-channel (mode)
  Use the port-channel mode global configuration command to select the way in which two Fast Ethernet ports aggregate using Port Aggregation Protocol (PAgP) to form a Fast EtherChannel link. Use the no port-channel mode command to disable Fast EtherChannel links.
  port-channel mode [on | auto | desirable | off]
  no port-channel mode
  Syntax Description
  on Forces the port to aggregate without negotiation.
  auto Port responds to PAgP packets it receives but does not initiate PAgP packet negotiation.
  desirable Port initiates negotiations with other ports by sending PAgP packets.
  off Prevents the port from aggregating without negotiation.
  
  Default
  Off
  Command Mode
  Global configuration
  Usage Guidelines
  When a Fast EtherChannel link is formed, the port-channel interface is enabled. The port channel remains enabled until both ports lose the link. In the case of port-channel auto or desirable mode, when a port-channel member port detects a partner port that is misconfigured, disabled, or is not bidirectional, the port-channel member port goes down.
  Both the auto and desirable modes allow ports to negotiate with connected ports to determine if they can form a channel based on criteria such as trunking state, VLAN numbers, and so on.
  This command is not functional when bridge groups are enabled.
  Example
  The following example shows how to create a Fast EtherChannel link when the PAgP status of connecting devices is uncertain:
  hostname(config)# port-channel mode desirable
  
  The following example shows how to create a channel interface and enable a Fast EtherChannel link with PAgP disabled.
  hostname(config)# port-channel mode on
  Related Commands
  pagp-port-priority
  port-channel (preserve-order)
  port-channel (template-port)
  show (interfaces)
  port-channel (preserve-order)
  Use the port-channel preserve-order global configuration command to preserve the frame transmission order on the channel interface. Use the no port-channel preserve-order command to allow frame transmission misordering on the channel interface.
  port-channel preserve-order
  no port-channel preserve-order
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  The default is no frame ordering.
  Command Mode
  Global configuration
  Usage Guidelines
  The no port-channel preserve-order command allows frame transmission misordering for maximum load balancing.
  This command is not functional when bridge groups are enabled.
  Example
  The following example shows how to preserve frame transmission order on the channel interface:
  hostname(config)# port-channel preserve-order
  Related Commands
  port-channel (mode)
  show (interfaces)
  port-channel (template-port)
  Use the port-channel template-port global configuration command to specify a Fast Ethernet port after which other grouped member ports are modeled.
  port-channel template-port template-port
  Syntax Description
  template-port For Catalyst 2820 switches, Fast Ethernet port 1 or 2.For Catalyst 1900 switches, Fast Ethernet port 26 or 27.
  
  Defaults
  Fast Ethernet port 1 for the Catalyst 2820 series switches.
  Fast Ethernet port 0/26 for the Catalyst 1900 series switches.
  Command Mode
  Global configuration
  Usage Guidelines
  The configuration parameters for which the specified Fast Ethernet port serves as a model or template are as follows:
  ?DISL trunk state.
  ?For a nontrunk port: VLAN number, spanning-tree path cost, and spanning-tree port priority.
  ?For a trunk port: VLAN allow list and VLAN Trunk Protocol (VTP) pruning-eligible list, spanning-tree two-option path costs and their assignments of VLANs, and spanning-tree two-option port priorities and their assignments of VLANs.
  The configuration parameters remain the same for all member ports after aggregation. After the group is created, any change to the parameters of any member port or port channel applies to all other ports in the group.
  This command is available only when bridge groups are enabled.
  Example
  The following example shows how to specify Fast Ethernet port 27 as the template port for member ports configuration:
  hostname(config)# port-channel template-port fastethernet 0/27
  Related Commands
  port-channel (mode)
  show (interfaces)
  port secure
  Use the port secure interface configuration command to enable addressing security. Use the no port secure command to disable addressing security or to set the maximum number of addresses allowed on the interface to the default value.
  port secure [max-mac-count count]
  no port secure [max-mac-count]
  Syntax Description
  max-mac-count Maximum number of addresses allowed on port.
  count Number from 1 to 132.
  
  Default
  The default is 132.
  Command Mode
  Interface configuration
  Example
  The following example shows how to set the maximum MAC address count to 100.
  hostname(config-if)# port secure max-mac-count 100
  
  The following example shows how to disable port security.
  hostname(config-if)# no port secure
  
  The following example shows how to set the MAC address count maximum to the default 132.
  hostname(config-if)# no port secure max-mac-count
  Related Commands
  interface
  port (block)
  port secure (clear)
  show (interfaces)
  show (mac-address-table security)
  port secure (clear)
  Use the port secure clear interface configuration command to enables the clearing of static addresses on a secure port when the link goes down. The no port secure clear command resets the port secure configuration to retain static addresses in the event of link failure.
  port secure clear
  no port secure clear
  Syntax Description
  This command has no arguments or keywords.
  Default
  Disabled
  Command Mode
  Interface configuration
  Usage Guidelines
  This command is available only on ports that have the port secure command enabled.
  Example
  This example shows how to set a port to clear its static addresses when the link is broken.
  hostname(config)# interface ethernet 0/1
  hostname(config-if)# port secure clear
  Related Commands
  port secure
  show (mac-address-table security)
  reload
  Use the reload privileged Exec command to immediately reset the switch or module.
  reload [type module]
  Syntax Description
  type Interface type: FDDI and ATM.
  module Interface number of a module: 1 or A for module 12 or B for module 2
  
  Default
  The entire switch is reset.
  Command Mode
  Privileged Exec
  Usage Guidelines
  After you enter this command, the system displays the following message:
  Reset system, [Y]es or [N]o ?
  
  Press Y or N as desired.
  After the reset, the switch or module retains all configured system parameters and static addresses and removes all dynamic addresses.
  Example
  The following example shows how to reset the entire switch:
  hostname# reload
  
  The following example shows how to reset the FDDI module in slot A.
  hostname# reload fddi A
  Related Command
  delete (nvram)
  reload (in)
  reload (in)
  Use the reload in privileged Exec command to specify the number of seconds before the switch resets.
  reload in
  Syntax Description
  seconds A value in seconds between 1 and 4294967.
  
  Default
  None
  Command Mode
  Privileged Exec
  Usage Guidelines
  If this command is executed again during the reset delay, the switch restarts the reset delay to the new delay time.
  Example
  This example shows how to reset the system in 10 seconds.
  hostname# reload in 10
  Related Commands
  delete (nvram)
  reload
  rip
  Use the rip global configuration command to enable the automatic discovery of IP gateways by running the Routing Information Protocol (RIP) listener. Use the no rip command to disable the RIP listener.
  rip
  no rip
  Syntax Description
  This command has no arguments or keywords.
  Default
  The RIP listener is enabled.
  Command Mode
  Global configuration
  Example
  The following example shows how to disable the RIP listener:
  hostname(config)# no rip
  Related Command
  ip (default-gateway)
  service (config)
  Use the service config global configuration command to enable automatic download of the switch configuration file from a Trivial File Transfer Protocol (TFTP) host during power up. Use the no service config command to disable automatic download of the configuration file.
  service config
  no service config
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  Auto configuration is disabled.
  Command Mode
  Global configuration
  Usage Guidelines
  
  Note If your switch is set up for auto configuration through Dynamic Host Configuration Protocol (DHCP), the DHCP auto configuration overrides the no service config command.
  
  Example
  The following example shows how to enable auto configuration:
  hostname(config)# service config
  Related Command
  show (running-config)
  copy (nvram tftp)
  copy (tftp)
  show (version)
  session
  Use the session Exec command to open a session to an ATM module with an independent operating system.
  session {number}
  Syntax Description
  number Module slot number:A or 1 for slot AB or 2 for slot B
  
  Default
  This command has no default value.
  Command Mode
  User and privileged Exec
  Example
  The following example shows how to open a session to the ATM module installed in slot B of the switch:
  switch> session B
  Related Commands
  None
  show (bridge-group)
  Use the show bridge-group privileged Exec command to display the current bridge group configuration and port membership.
  show bridge-group
  Syntax Description
  This command has no additional arguments or keywords.
  Default
  This command has no default value.
  Command Mode
  Privileged Exec
  Usage Guidelines
  This command is available only when bridge groups are enabled.
  Example
  The following example shows how to display the current bridge-group configuration and port membership:
  hostname# show bridge-group
  
  Allow overlapping bridge-groups: Disabled
  Bridge GroupMember Ports
  ------------------------------------------------------------------------------------
  12, 4, 5, 9-20
  221-25
  31, 3, 6, 7, 8
  4A, B
  Related Commands
  bridge (forwarding-time)
  bridge (hello-time)
  bridge (max-age) 更多请看Cisco与华为技术网(Vlan9.com)三层交换交换机与路由器密码恢复交换机选购专题,或进入论坛讨论。